Nivelor Maxi Top – self-leveling screed
Class C25F7B2.0A22 – According to EN 13813:2003
Self-leveling screed from 2 to 20 mm
Category: Self-leveling screeds
Description:
PURPOSE
NIVELOR MAXI TOP is a dry calcium-sulphate mixture with added mineral fillers and special polymers, for internal application.
The product is designed for leveling with thickness of the layer from 2 to 20 mm, of uneven floor areas. It is suitable for applying on different bases such as concrete floors, calcium-sulphate or cement-based surfaces, in new buildings or when repairing old indoor rooms.
NIVELOR MAXI TOP has high wear resistance and short-term drying abilities. With its high-strength characteristics, the product is recommended for fine leveling on floors with integrated floor-heating installations.
Before applying of NIVELOR STANDARD the base should be primed with TERAZID G-101.
The product’s characteristics allow walking on the screed 4-5 hours after its application, with thickness of the layer – 10 mm. The following building operations should start 3-5 days later, considering the self-leveling screed’s humidity and the type of the floor covering, which is going to be applied.
Maximum thickness of the layer – up to 20 mm.
Declaration of Performance (DoP)
Nivelor Maxi Top – self-leveling screed
Declaration of Performance (DoP)
NIVELOR MAXI TOP
DECLARATION OF PERFORMANCE
According with Regulation (EU) №305/2011
№ 20130709-55-D
1. Unique identification code of product type:
NIVELOR MAXI TOP
2. Type, batch or serial number or other element allowing identification of the construction product as required under Article 11, paragraph 4 of Regulation (EU) №305/2011:
Calcium-sulphate self-leveling screed
/batch number printed on the package/
3. Intended use or uses of the construction product in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer:
Self-leveling mixture for floor unevenness from 2 to 20 mm, for interior application.
4. Name, registered trade name or registered trade mark and contact address of the manufacturer, as required under Article 11, paragraph 4 of Regulation (EU) №305/2011:
TERAZID Ltd.
5 „5004” Str., Gara Iskar, Sofia 1528, Bulgaria
tel. +35929799971
e-mail: office@terazid.com
5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12, paragraph 2 of Regulation (EU) №305/2011:
Not applicable.
6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Regulation (EU) №305/2011 for construction products, Annex V:
System 4
7. In case of the declaration of performance concerning a construction product covered by harmonized standard:
BDS EN 13813 – Screed material and floor screeds – Screed material – Properties and requirements
8. Declared performance
Essential characteristics | Performance | Harmonized technical specification |
---|---|---|
Reaction to fire | Class A1 | BDS EN 13820 |
Compressive strength | 26.8 N/mm² Class C25 |
BDS EN 13892-2 |
Bond strength | 3.3 N/mm² Class B2.0 |
BDS EN 13892-8 |
Flexural strength | 7.0 N/mm² Class F7 |
BDS EN 13892-2 |
Abrasion resistance (Böhme method) | 35.6 cm³/50 cm² Class A22 |
BDS EN 13892-3 |
Coefficient of capillary absorption of water – c | 0.29 kg/m²·h0.5 | BDS EN 1062-3 |
9. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8. This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.
Technical Data Sheet (TDS)
Nivelor Maxi Top – self-leveling screed
Technical Data Sheet (TDS)
NIVELOR MAXI TOP
Self-levelling screed for interior application from 2 to 20 mm
In accordance with EN 13813:2003 – class C25F7B2,0A22
Dry calcium-sulphate mixture for levelling of indoor premises
PURPOSE
NIVELOR MAXI TOP is a dry calcium-sulphate mixture for leveling of uneven indoor floors, with a thickness of applying from 2 to 20 mm. It is suitable for applying on different bases, such as concrete, calcium-sulphate, magnesite, or cement-based surfaces. The product characteristics, such as the excellent spreading ability, short drying terms, and high wear-resistance, allow NIVELOR MAXI TOP to be used on floors with integrated heating systems.
PROPERTIES
-
Fastness and precision at application
-
From 2 to 20 mm
-
Short periods of drying
-
High wear resistance
-
Suitable for floor heating systems
PREPARATION OF THE BASE
The base should be strong, dry, free from oil, dust, sand, and other contaminants or separating layers. The concrete bases should have reached their optimal strength (after 28 days). Before applying NIVELOR MAXI TOP, the base should be primed with TERAZID G-101 (for low-absorbing substrates) or TERAZID G-202 (for high-absorbing substrates). The self-leveling screed should be applied after the primer is completely dry.
CHARACTERISTICS AND TECHNICAL DATA
-
Colour: grey
-
Base: calcium-sulphate
-
Bulk weight: over 1.1 kg/l
-
Work temperature: +5˚C to +25˚C
-
Time for ‘maturing’: 5-10 minutes
-
Open time (for work): 60 minutes
-
Maximum thickness of the layer: up to 20 mm
-
Ready for walking after: around 5 hours
-
Time for final bounding and subsequent operations: 3-5 days
-
Compressive strength after 28 days: 26.8 N/mm²
-
Flexural strength after 28 days: 7.0 N/mm²
-
Abrasion resistance on the 28th day (Böhme method): 35.6 cm³/50 cm²
APPLICATION AND PROCESSING
To fully dissolve the 25 kg of NIVELOR MAXI TOP, around 6 liters of water are required. Into a preliminary prepared container with water, the necessary amount of dry mixture is poured and stirred with a mechanical mixer until a homogeneous mass is achieved. Thus, the stirred mixture is left to stay for about 5-10 minutes, after that it is stirred once again and it is ready for work. It is desirable to prepare as much quantity of NIVELOR MAXI TOP as it could be applied for a period of 60 minutes. Spill the screed over the working area and spread it with a stainless mortarboard till the necessary thickness is achieved. The work starts from the farthest corner of the room, gradually moving towards the door. If necessary, the freshly applied layer is deaerated with a special needle roller. It is advisable to work with special shoes, fitted with spikes.
NIVELOR MAXI TOP characteristics allow walking on the screed 4-5 hours after its application, with a thickness of the layer – 10 mm. Subsequent construction operations should start after 3-5 days, considering the screed humidity and the type of the covering that is going to be applied.
CONSUMPTION
1.4 – 1.6 kg/m² with a thickness of the layer of 1 mm.
TOOLS FOR WORK
-
Electrical drill and stirrer
-
Steel mortar-board with long handle
-
Needle roller
-
Shoes with spikes
WEATHER CONDITIONS AT WORK
The minimum twenty-four-hour temperature of the air and the base should not be less than +5˚C, and the maximum – not higher than +25˚C. Lower temperatures could extend processing time, and higher temperatures could reduce it. After application of the self-levelling screed, a temperature of +5˚C to +25˚C should be ensured. Avoid application under direct sunlight or strong air drafts.
FORM OF DELIVERY
Dry mixture in paper bags of 25 kg
NOTES
Characteristics and technical data of the product, pointed out in this Technical Data Sheet, are defined at a standard temperature (20˚C) and relative humidity (50%). In other weather conditions, the technological time for some of the processes mentioned above could be shorter or longer.
The information of the product is based on the practical experience of the manufacturer and the technical tests in specialized laboratories.
Do not mix with other building materials.
All hazards and precautionary statements about NIVELOR MAXI TOP can be checked in the Safety Data Sheet of the product.
STORAGE
6 months into originally sealed packages, in a dry and ventilated store. It is recommended to be stored on pallets.
Essential characteristics | Performance | Harmonized technical specification |
---|---|---|
Reaction to fire | Class A1 | BDS EN 13813 |
Compressive strength | 26.8 N/mm² | BDS EN 13813 |
Bond strength | 3.3 N/mm² | BDS EN 13892-8 |
Flexural strength | 7.0 N/mm² | BDS EN 13892-2 |
Abrasion resistance (Böhme method) | 35.6 cm³/50 cm² | BDS EN 13892-3 |
Coefficient of capillary absorption of water – c | 0.29 kg/m²·h0.5 | BDS EN 1062-3 |
Material Safety Data Sheet (MSDS)
Nivelor Maxi Top – self-leveling screed
Material Safety Data Sheet (MSDS)
NIVELOR MAXI TOP
MATERIAL SAFETY DATA SHEET
According to (EU) 830/2015
1. Identification of the Substance/Mixture and of the Company
1.1. Product identifier – NIVELOR MAXI TOP
1.2. Application of the substance
Dry mixture for interior self-levelling screeds.
1.3. Details of the supplier of the safety data sheet
TERAZID Ltd.
5, 5004 Street, Gara Iskar1528 Sofia, Bulgaria
tel. +359 2 9799971, office@terazid.com
1.4. Emergency telephone number (EU) 112
UMHATEM “Pirogov” (toxicology) – +3592/9154409; +3592/9154233
2. Hazards Identification
2.1. Classification of the substance or mixture
-
Classification in accordance with Regulation (ЕО) 1272/2008 – CLP: The product is classified as “dangerous”.
2.2. Label elements
Hazard pictograms:
Signal word: Danger!
Hazard statements:
H315 – Causes skin irritation.
H318 – Causes serious eye damage.
H335 – May cause respiratory irritation.
2.3. Precautionary statements
-
P101 – If medical advice is needed, have product container or label at hand.
-
P102 – Keep out of reach of children.
-
P261 – Avoid breathing dust/fume/gas/mist/vapours/spray.
-
P280 – Wear protective gloves/protective clothing/eye protection/face protection.
-
P302 + P352 – IF ON SKIN: Wash with plenty of soap and water.
-
P332 + P313 – If skin irritation occurs: Get medical advice/attention.
-
P305 + P351 + P315 – IF IN EYES: Rinse cautiously with water for several minutes. Get immediate medical advice/attention.
-
P402 – Store in a dry place.
2.3. Other hazards
-
Contains portland cement. When reacting with water, it creates an alkaline medium.
-
Does not contain soluble Cr (VI) in a quantity greater than 0.0002% within the period of storage.
For all warnings and recommendations, see Section 15.
3. Composition/information on ingredients
-
General chemical description: Self-levelling screed based on portland cement, mineral fillers, and modifying additives.
Information of the substances in accordance with CLP 1272/2008/EC
CAS № EINECS № |
Name | Concentration (%) | Signal word | H-codes |
---|---|---|---|---|
65997-15-1 266-043-4 |
Grey cement | 20-30 | Hazardous | H315, H318, H335 |
All warnings can be seen in Section 15.
4. First Aid Measures
4.1. Description of the first aid measures
-
Inhalation: Remove the person to fresh air. If the symptoms continue, immediately seek qualified medical help.
-
Skin contact: Immediately rinse the area of contact with plenty of water, then wash it thoroughly with soap and water.
-
Eye contact: Irrigate with plenty of water for at least 15 minutes and open eyelids. Seek qualified medical help.
-
Ingestion: Do NOT induce vomiting. Seek qualified medical help.
4.2. Most important symptoms and effects, both acute and delayed
-
In contact with the eyes: irritation.
-
In contact with the skin: redness, inflammation.
4.3. Indication of any immediate medical attention and special treatment needed
-
See p. 4.1.
5. Firefighting Measures
-
NIVELOR MAXI TOP is a non-combustible and non-explosive product.
5.1. Extinguishing media
-
Water mist, water spray – sprayer, dry chemical, foam, carbon dioxide.
-
Inappropriate means for extinguishing fire: Not known.
5.2. Special hazards, arising from the substance or mixture
-
None known.
5.3. Advice for firefighters
-
Autonomous respiratory equipment.
6. Accidental Release Measures
6.1. Personal precautions, protective equipment, and emergency procedures
-
Gloves, masks, protective clothing for work. Contact with skin and eyes should be avoided.
6.2. Environmental precautions
-
(Content for environmental precautions is not included in this text.)
Prevent this product from being released into the environment. Measures should be taken to prevent contamination of surface and underground watercourses, soil, and prevent it from falling into drains.
In the event of an accident and/or spill of the product, measures for localization and limitation should be taken. The collected amount of the product should be temporarily stored in special, tightly closed, and labeled containers, and then transferred to people holding permits under Article 37 of the Waste Management Act.
6.3. Methods and materials for containment and cleaning up
The spilled amount should be mechanically removed, taking measures to prevent the formation of high concentrations of dust in the air. The amount in the form of dust or unhardened mixture should be rinsed with water and soap.
The collected amount should be stored in special, tightly closed and labeled containers and temporarily stored on the company’s premises, then transferred to people holding a permit under the Waste Management Act (WMA).
7. Handling and Storage
7.1. Precautions for safe handling
The product should be used only according to its main purpose. Do not eat, drink, or smoke during work. Avoid the formation of dust and ensure proper ventilation of the room. Avoid contact with skin and eyes.
7.2. Conditions for safe storage, including any incompatibilities
It should be stored in ventilated and dry places, in the originally sealed packages. Temperatures lower than 0°C and higher than +50°C should be avoided. It should be separately stored from food and drinks.
7.3. Specific Usage
There is no specific usage. It should be used only according to its main purpose.
8. Exposure Controls/Personal Protection
8.1. Control parameters
-
Portland cement – permitted level of inhaled powder particles: 5 ppm / 5 mg/m³ air.
8.2. Exposure controls
-
8.2.1. Respiratory protection – Use a mask to prevent inhalation of dust, filter P2.
-
8.2.2. Skin protection – Skin contact should be avoided, wear protective gloves.
-
8.2.3. Eye protection – Eye contact should be avoided, wear safety glasses.
-
8.2.4. Common protection – It should be stored away from food, drinks, and food for animals.
9. Physical and Chemical Properties
9.1. Information on basic physical and chemical properties
-
Appearance: Fine powder
-
Color: Grey
-
Odor: None
-
pH at 20°C: Approximately 8.0
-
Density: 1150 kg/m³
-
Solubility: Insoluble
-
Explosive properties: Non-explosive
9.2. Other information
No data.
10. Stability and Reactivity
10.1. Reactivity
The product reacts with moisture and hardens.
10.2. Chemical stability
The product is stable under storage and usage in accordance with the indications.
10.3. Possibility of hazardous reactions
As stated in section 10.1, the product reacts with moisture and hardens.
10.4. Conditions to avoid
The product should be kept away from moisture during storage and transportation.
10.5. Incompatible materials
No data available.
11. Toxicological Information
11.1. Information for the toxicological effects
Toxicological properties of the product are not tested. The product is classified under the conventional method in accordance with Regulation (ЕО) 1272/2008 – CLP. Based on its composition, the product can be defined as not having any toxic effects under proper usage.
-
Ingestion – It is less likely that ingestion will lead to a reaction or long-term effects, but it is recommended to be avoided.
-
Inhalation – Dust can cause irritation in the nose, throat, and lungs, leading to coughing.
-
Skin contact – In combination with heat and sweat, the product can cause irritation, but it is not absorbed through the skin.
-
Eye contact – The product can cause serious eye damage.
12. Ecological Information
12.1. Toxicity
It is not expected that the product is hazardous to the environment (LC50 toxicity in water – not defined). However, adding large amounts of water can lead to an increase in pH, which could be toxic to aquatic organisms under certain conditions.
12.2. Persistence and degradability
No data available.
12.3. Bio-accumulative potential
Low potential for bioaccumulation.
12.4. Mobility in soil
The product is a hard, non-organic material.
12.5. Results of PBT and vPvB assessment
The product does not meet the criteria for PBT (persistent, bioaccumulative, and toxic) and vPvB (very persistent and very bio-accumulative).
12.6. Other adverse effects
No data available.
13. Disposal Considerations
Product waste, such as residual quantities and packages, should be collected in special, tightly sealed, and labeled containers, temporarily stored, and then transferred to authorized personnel holding a permit in accordance with Article 37 of the Waste Management Act (Publication SG, Issue 53, 2012).
Waste code, in accordance with Regulation №2 from 23.07.2014 for Waste Classification:
-
10 13 – Waste from the production of cement, lime, gypsum, and items and products made of these materials.
-
10 13 14 – Waste concrete and concrete sediment.
-
15 01 – Packages.
-
15 01 10 – Packages containing residues of hazardous substances or contaminated with hazardous substances.
Completely empty the packages and dispose of them in accordance with local regulations, at designated places for paper waste.
14. Transport Information
The product is not a hazardous load, in accordance with RID, ADR, ADNR, IMDG, IATA-DGR.
It should be transported under the respective rules for transportation, considering the respective type of transport and ensuring the safety of the load.
15. Regulatory Information
15.1 Classification and labeling of the product in accordance with Regulation (ЕО) 1272/2008 – CLP /full text of the codes/
-
GHS Pictograms:
-
Signal word: Danger!
-
Hazard statements (H-codes):
-
H315 – Causes skin irritation.
-
H318 – Causes serious eye damage.
-
H335 – May cause respiratory irritation.
-
-
Precautionary statements (P-codes):
-
P101 – If medical advice is needed, have product container or label at hand.
-
P102 – Keep out of reach of children.
-
P261 – Avoid breathing dust/fume/gas/mist/vapours/spray.
-
P280 – Wear protective gloves/protective clothing/eye protection/face protection.
-
P302 + P352 – IF ON SKIN: Wash with plenty of soap and water.
-
P332 + P313 – If skin irritation occurs: Get medical advice/attention.
-
P305 + P351 + P315 – IF IN EYES: Rinse cautiously with water for several minutes. Get immediate medical advice/attention.
-
P402 – Store in a dry place.
-
15.2 Legislation
National Legislation:
-
Law of Protection from the Harmful Impact of the Chemical Substances and Preparations.
-
Environmental Protection Law.
-
Health and Safety at Work Act.
-
Ordinance №3 on the minimum requirements for safety and protection of the workers when using personal protective equipment at the workplace.
-
Waste Management Act.
-
Ordinance №2 from 23.07.2014 for Waste Classification.
-
Ordinance on the order and the method of classification, labeling, and packaging of chemical substances and preparations.
European Legislation:
-
Regulation (ЕО) 1272/2008 – CLP from 16th December 2008, concerning the classification, labelling and packaging of substances and preparations.
-
Regulation (ЕО) 830/2015 from 28th May 2015.
16. Other Information
16.1. Indication of changes
Format in accordance with Regulation (ЕО) 830/2015 from 28th May 2015 amending Regulation № 1907/2006 (REACH) of the European Parliament.
16.2. Training advice
In addition to the training programs on environment and health and safety of the workers, the companies need to be sure that their workers read, understand and apply the requirements of the MSDS.
16.3. Additional information
See the application(s) of exposure scenarios for the following substances:
The basic information of the exposure scenarios of the substances in the mixture are included in points 1, 2, 3, 8, 11, and 12.
16.4. Disclaimer
This safety data sheet and the data inside of it are based on industrial and commercial experience of many years and are fully complied with the current active legislation of the Republic of Bulgaria and the European Union.
This safety data sheet is not intended to guarantee any specific properties and qualities of the product. The information inside of it is reliable but, on the circumstance, that the product is used in accordance with the indicated conditions and the application, specified on the package and/or in the technical literature.
Responsibility of any other use of the product, including when using it in combination with another product or process is completely under the responsibility of the user. It is understood that the user is responsible for defining the appropriate precautions and for applying the legislation, concerning his own activity.
Technical Data
Open time for work | 55-60 min. |
Ready for walking after | 4-5 h (for 10 mm layer thickness) |
Final bonding | from 3 to 5 days |
Thickness of applying | up to 20 mm |
Consumption | 1.4-1.6 kg/m² (for 1 mm layer thickness) |
Package | 25 kg |
Price | on request |
Pieces | 42 pcs/pallet |