Termozid – hydrophobic mixture for bonding and plastering of EPS and XPS
According to EN 13499:2004
Hydrophobic mixture for bonding and plastering of EPS and XPS thermal insulation boards
Component of thermal insulation system certified according ETAG 004, ETA 13/021
Colours : grey, white
Category: Products for therm-insulation systems
Description:
PURPOSE
TERMOZID is a high-quality cement-based product, with special additives, designed for bonding and plastering of EPS and XPS thermal insulation boards, on external and internal walls and ceilings.
The material is suitable for building of new facades, as well as for renovation of old buildings.
TERMOZID has excellent adhesion to different types of bases, such as bricks and concrete. The high resistance to moisture, mechanical strength and vapour-permeability determine the product’s application as base-coat plaster for expanded and extruded polystyrene, protecting the insulation boards from aging and mechanical injuries, and ensuring water-repellence and crack
resistance.
It creates an excellent base for decorative finishing coats such as facades plasters and paints.
Declaration of Performance (DoP)
Termozid – hydrophobic mixture for bonding and plastering of EPS and XPS
Declaration of Performance (DoP)
DECLARATION OF PERFORMANCE
According with Regulation (EU) №305/2011
TERMOZID
№ 20130709-41-D
1. Unique identification code of product type:
TERMOZID
2. Type, batch, or serial number or other element allowing identification of the construction product as required under Article 11, paragraph 4 of Regulation (EU) №305/2011:
Adhesive and reinforcement base-coat plaster for insulation boards (batch number printed on the package)
3. Intended use or uses of the construction product in accordance with the applicable harmonized technical specification, as foreseen by the manufacturer:
Hydrophobic mixture for bonding and plastering of EPS and XPS thermal insulation boards
4. Name, registered trade name or registered trademark, and contact address of the manufacturer as required under Article 11, paragraph 4 of Regulation (EU) №305/2011:
TERAZID Ltd.
5 „5004” Str., Gara Iskar, Sofia 1528, Bulgaria
Tel.: +359 2 979 9971
E-mail: office@terazid.com
5. Where applicable, name and contact address of the authorised representative whose mandate covers the tasks specified in Article 12, paragraph 2 of Regulation (EU) №305/2011:
Not applicable.
6. System or systems of assessment and verification of constancy of performance of the construction product as set out in Regulation (EU) №305/2011 for construction products, Annex V:
System 2+
7. In case of the declaration of performance concerning a construction product for which a European Technical Assessment was issued:
ETAG 004 — The notified body 1020 – Technical and Test Institute For Construction Prague has issued European Technical Assessment ETA-13/0214 according to ETAG 004.
The notified body has performed:
-
Initial inspection of the factory and of the factory production control
-
Continuous surveillance, assessment, and approval of the factory production control
The notified body has issued the EC Certificate of Factory Production Control №1020-CPD-060037435.
This certificate attests that all provisions concerning the attestation of factory production control, described in ETA-13/0214, were applied.
8. Declared performance:
TERAZID Ltd. 5 “5004” Str. Gara Iskar, Sofia, Bulgaria |
||
---|---|---|
Essential characteristics | Performance | Harmonized technical specification |
Reaction to fire | Class A1 | BDS EN 13820 |
Density | 1850 kg/m³ | BDS EN 1015-6 |
Adhesion with the concrete base | 1.5 N/mm² | BDS EN 1542 |
Bond strength with EPS slab | 280 kPa | BDS EN 13494 |
Coefficient of water vapour permeability | 190 g/m²·d·Pa V1 |
BDS EN ISO 7783-2 |
Coefficient of capillary absorption of water – c | 0.16 kg/m²·h0.5 class W2 |
BDS EN 1062-3 |
Compressive strength | 23.5 MPa | BDS EN 1015-11 |
Class C2 according to BDS EN 12004 | ||
Initial tensile bond strength | 1.9 N/mm² | BDS EN 12004-2 |
Tensile bond strength after water immersion | 1.1 N/mm² | BDS EN 12004-2 |
Tensile bond strength after heat treatment | 1.9 N/mm² | BDS EN 12004-2 |
Tensile bond strength after 25 freeze-thaw cycles | 1.0 N/mm² | BDS EN 12004-2 |
9. The performance of the product identified in points 1 and 2 is in conformity with the declared performance in point 8.
This declaration of performance is issued under the sole responsibility of the manufacturer identified in point 4.
Technical Data Sheet (TDS)
Termozid – hydrophobic mixture for bonding and plastering of EPS and XPS
Technical Data Sheet (TDS)
TECHNICAL DATA SHEET
TERMOZID
Adhesive and Reinforcement Base-Coat Plaster for Insulation Boards
According to the requirements of ETAG 004
Cement-based hydrophobic mixture for bonding and plastering of EPS and XPS thermal insulation boards
PURPOSE
TERMOZID is a cement adhesive and base-coat plaster based on grey or white cement, with added fine mineral fillers, reinforced mono fibres, and polymer additives.
It is designed for bonding boards of expanded polystyrene (EPS), extruded polystyrene (XPS), and mineral wool slabs to walls and ceilings for both internal and external insulation of buildings.
The material is suitable for constructing new walls as well as for renovating old buildings.
TERMOZID is also applied for bonding insulation over roof constructions, cold floors, swimming pools, saunas, and similar areas.
Application of a protective reinforcement base-coat with TERMOZID prevents insulation boards from “aging” and protects them from weather influences. It ensures waterproofing and crack resistance of the finished layer, while also protecting the insulation layer from mechanical damage.
It creates an excellent base for decorative facade finishes with fine plaster or paint.
TERMOZID is a component of the External Thermal Insulation Composite System TERAZID BIO CLIMA, approved with ETA – 13/0214.
It is classified as a Class C2 cement-based product according to EN 12004 — Adhesives for tiles — Requirements, evaluation of conformity, classification, and designation.
PROPERTIES
-
Easy to apply
-
Sufficient open time (for work)
-
Cold resistant
-
Impact resistant (with 4 mm thickness of the layer)
-
Vapour-permeable
PREPARATION OF THE BASE
TERMOZID has excellent adhesion to various construction surfaces such as bricks, concrete, plasters, cement, and gypsum base-coats.
Before starting work, the base must be dry, dust-free, and well cleaned from separating construction particles (oil, bitumen, old plaster, etc.).
Old unstable plasters and coatings must be removed.
For highly absorbent bases such as aerated concrete or gypsum blocks, it is recommended to prime in advance with a deeply penetrating primer TERAZID G-55.
CHARACTERISTICS AND TECHNICAL DATA
-
Colour: Grey or white
-
Base: Cement
-
Density: 1.5 kg/l
-
Work temperature: +5°C to +30°C
-
Time for “maturing”: 6–7 minutes
-
Time for bucket stay: About 5 hours
-
Open time for work: 30 minutes
-
Time for final bonding and subsequent operations: 7 days
-
Recommended thickness of the base-coat layer: 4–5 mm
INSTRUCTIONS FOR APPLICATION AND PROCESSING
For complete dissolution of 25 kg of TERMOZID, approximately 6.5 litres of water are required.
In a pre-prepared container, pour the necessary amount of dry mixture into water and stir using a mechanical mixer until a homogeneous mass is achieved.
Let the stirred mixture mature for 6–7 minutes, then stir it again before use.
Bonding:
-
On smooth and flat surfaces, the prepared solution is applied like a comb using a notched mortar-board with edges of 8–10 mm.
-
On rough surfaces, the solution is applied around the entire outer rim of the insulation panel in a strip 4–5 cm wide, and in a few spots on the inner side as “pillows”.
Note:
Additional fixing with anchors can start no earlier than 24 hours after bonding (at temperatures not lower than 20°C).
Plastering:
After the boards are anchored, TERMOZID can be used as a base-coat.
The solution is applied uniformly, and the fiberglass reinforcement mesh is embedded vertically, tightly pressed, and smoothed using a mortar-board.
The recommended base-coat thickness is 4–5 mm.
CONSUMPTION
-
Bonding: 5–5.5 kg/m² depending on the base
-
Plastering: 3.5–4.0 kg/m²
TOOLS FOR WORK
-
Bucket
-
Electrical drill and stirrer
-
Trowel
-
Mortar-board
-
Lute
WEATHER CONDITIONS AT WORK
The minimum 24-hour temperature of the air and base should not be lower than +5°C, and the maximum should not exceed +30°C.
Application is not recommended during high humidity, rain, or when rain is forecasted.
FORM OF DELIVERY
-
Dry mixture in paper packages of 25 kg
NOTES
-
Characteristics and technical data in this Technical Data Sheet are defined at a standard temperature of 20°C and relative humidity of 50%.
Under different weather conditions, the technological times for some processes may vary. -
The product information is based on the manufacturer’s practical experience and technical laboratory tests.
-
Do not mix with other building materials.
-
All hazard and precautionary statements regarding TERMOZID can be found in the product’s Safety Data Sheet.
STORAGE
-
Shelf life: 12 months in originally sealed packages
-
Storage conditions: Store in a dry and ventilated place. It is recommended to store the product on pallets.
CE | ||
TERAZID Ltd. | ||
5 “5004” Str. Gara Iskar, Sofia, Bulgaria | ||
ETAG 004 | ||
NB 1020 | ||
DoP № 20130709-41-D | ||
TERMOZID | ||
Adhesive and reinforcement base-coat plaster for insulation boards | ||
Reaction to fire | A1 | |
Bulk density | 1850 kg/m³ | |
Bond strength with concrete base | 1.5 N/mm² | |
Bond strength with EPS slab | 280 kPa | |
Compressive strength | 23.5 MPa | |
Coefficient of capillary absorption of water – c | 0.16 kg/m²·h0.5 class W2 |
|
Coefficient of water vapour transmission | 190 g/m²·d·Pa V1 |
|
Class C2 according to BDS EN 12004 | ||
Initial tensile bond strength | 1.9 N/mm² | |
Tensile bond strength after water immersion | 1.1 N/mm² | |
Tensile bond strength after heat treatment | 1.9 N/mm² | |
Tensile bond strength after 25 freeze-thaw cycles | 1.0 N/mm² |
The manufacturer recommends checking the suitability of the product in the Technical Data Sheet. The same is responsible for the product quality, but not for the ways and conditions of its applying. The information into the present Technical Data Sheet is reliable but only if the product is used under stated conditions. The responsibility of any other usage of the product, including its usage in a combination with any other product or a process, is borne by the user.
Material Safety Data Sheet (MSDS)
Termozid – hydrophobic mixture for bonding and plastering of EPS and XPS
Material Safety Data Sheet (MSDS)
MATERIAL SAFETY DATA SHEET
According to (EU) 830/2015
TERMOZID
1. Identification of the Substance/Mixture and of the Company
1.1. Product identifier – TERMOZID 1.2. Application of the substance Cement-based mixture for bonding and reinforcing of insulation boards 1.3. Details of the supplier of the safety data sheet TERAZID Ltd. 5, 5004 Street, Gara Iskar1528 Sofia, Bulgaria tel. +359 2 9799971, office@terazid.com 1.4. Emergency telephone number (EU) 112 UMHATEM “Pirogov” (toxicology) – +3592/9154409; +3592/9154233
2. Hazards Identification
2.1. Classification of the substance or mixture – Classification in accordance with Regulation (ЕО) 1272/2008 – CLP: The product is classified as „dangerous“. 2.2. Label elements Hazard pictograms:
Signal word: Danger!
Hazard statements: H315 – Causes skin irritation. H318 – Causes serious eye damage. H335 – May cause respiratory irritation. Precautionary statements: P101 – If medical advice is needed, have product container or label at hand. P102 – Keep out of reach of children. P261 – Avoid breathing dust/fume/gas/mist/vapours/spray. P280 – Wear protective gloves/protective clothing/eye protection/face protection. P302 + P352 – IF ON SKIN: Wash with plenty of soap and water. P332 + P313 – If skin irritation occurs: Get medical advice/attention. P305 + P351 + P315 – IF IN EYES: Rinse cautiously with water for several minutes. Get immediate medical advice/attention. P402 – Store in a dry place.
2.3. Other hazards Contains portland cement. When reacting with water, it creates an alkaline medium. Does not contain soluble Cr (VI) into a quantity greater than 0,0002 % within the period of storage. For all warnings and recommendations, see Section 15.
3. Composition/information on ingredients
General chemical description: Adhesive and base-coat plaster on the basis of portland cement, mineral fillers and modifying additives. Information of the substances in accordance with CLP 1272/2008/EC
CAS № EINECS № |
Name | Concentration (%) | Signal word | H-codes |
---|---|---|---|---|
65997-15-1 266-043-4 |
Grey cement | 20–40 | Hazardous | H315, H318, H335 |
All warnings can be seen in Section 15
4. First Aid Measures
4.1. Description of the first aid measures Inhalation – Remove the person to fresh air. If the symptoms continue, immediately seek for qualified medical help. Skin contact – Immediately rinse the area of the contact with plenty of water, then wash it thoroughly with soap and water. Eye contact – Irrigate with plenty of water for a period of at least 15 minutes and open eyelid. Seek for qualified medical help. Ingestion – Do NOT induce vomiting. Seek for qualified medical help. 4.2. Most important symptoms and effects, both acute and delayed In contact with the eyes: irritation. In contact with the skin: redness, inflammation. 4.3. Indication of any immediate medical attention and special treatment needed – see p. 4.1.
5. Firefighting Measures
TERMOZID is non-combustible and non-explosive product. 5.1. Extinguishing media Water mist, water spray – sprayer, dry chemical, foam, carbon dioxide. Inappropriate means for extinguishing fire – Not known. 5.2. Special hazards, arising from the substance or mixture – Non known 5.3. Advice for firefighters: Autonomous respiratory equipment.
6. Accidental Release Measures
6.1. Personal precautions, protective equipment and emergency procedures Gloves, masks, protective clothing for work. Contact with skin and eyes should be avoided.6.2. Environmental precautions Prevent this product from release in the environment. Measures should be taken for preventing contamination of surface and underground watercourses, soil, as well as falling into the drains. In the event of an accident and/or spill of the product, measures for localization and limitation should be taken, and the collected amount of the product should be temporarily stored into a special, tightly closed and labeled containers, and after that they should be transferred to people, holding permits under the Article 37 of the Waste Management Act. 6.3. Methods and materials for containment and cleaning up The spilled amount should be mechanically removed, by taking measure to prevent formation of high concentration of dust in the air. The amount in the form of dust or unhardened mixture should be rinses with water and soap. Collected amount should be stored in special, tightly closed and labeled containers and to be temporarily stored on the territory of the company, and after that they should be transferred to people, holding a permit under the Waste Management Act (WMA).
7. Handling and Storage
7.1. Precautions for safe handling The product should be used only according to its main purpose. Do not eat, drink or smoke during work. Avoid formation of dust and often ventilate the room. Avoid skin and eye contact. 7.2. Conditions for safe storage, including any incompatibilities It should be stored in ventilated and dry places, into the originally sealed pakcages. Temperatures lower than 0C and higher than +50C should be avoided. It should be separately stored from food and drinks. 7.3. Specific Usage There is no specific usage. It should be used only according to its main purpose. 8. Exposure Controls/Personal Protection 8.1. Control parameters Portland cement – permitted level of inhaled powder particles: 5 ppm/5 mg/m³ air/. 8.2. Exposure controls 8.2.1. Respiratory protection – use a mask preventing from inhaling dust, filter P2. 8.2.2. Skin protection – skin contact should be avoided, wear protective gloves. 8.2.3. Eye protection – eye contact should be avoided, wear safety glasses. 8.2.4. Common protection – it should be stored away from food, drinks and food for animals.
9. Physical and Chemical Properties
9.1. Information on basic physical and chemical properties
-
Appearance: Fine powder
-
Color: Grey or white
-
Odor: None
-
pH at 20°C: Approximately 7.8
-
Density: 1850 kg/m³
-
Solubility: Insoluble
-
Explosive properties: Non-explosive
9.2. Other information – no data.
10. Stability and reactivity
10.1. Reactivity – the product reacts with the moisture and gets hardened. 10.2. Chemical stability – the product is stable under storage and usage in accordance with the indications. 10.3. Possibility of hazardous reactions – in accordance with section 10.1. 10.4. Conditions to avoid – it should be kept away from moisture at storage and transportation. 10.5. Incompatible materials – no data.
11. Toxicological Information
11.1. Information for the toxicological effects Toxicological properties of the product are not tested. The product is classified under the conventional method in accordance with Regulation (ЕО) 1272/2008 – CLP. On the basis of its composition, the product can be defined as not having any toxic effects under a proper usage. The product is not hazardous of acute poisoning. Ingestion – It is less likely that the ingestion will lead to reaction or long-term effect, but is recommended to be avoided. Inhalation – Dust can cause irritation in the nose, the throat and the lungs, leading to coughing. Skin contact – In combination with heat and sweat, the product can cause irritation, but is not absorbed through the skin. Eye contact – The product can cause serious eye damage.
12. Ecological Information
12.1. Toxicity It is not expected that the product is hazardous for the environment (LC50 toxicity in water – it is not defined). Adding large amounts of water, however, can lead to rising of pH and therefore it can appear to be toxic to aquatic organisms at certain conditions. 12.2. Persistence and degradability – No data. 12.3. Bio-accumulative potential – Low potential of bioaccumulation. 12.4. Mobility in soil Hard product with non-organic origin. 12.5. Results of PBT and vPvB assessment – the product does not meet the criteria of PBT (persistent, bioaccumulative and toxic) and vPvB (very persistent and very bio-accumulative). 12.6. Other adverse effects No data.
13. Disposal Considerations
Product waste, such as residual quantities and packages, should be collected into a special, tightly sealed and labeled containers, temporarily stored, and after that to be transferred to people, holding a permit in accordance with article 37 of the Waste Management Act (publication SG, issue 53, 2012). Waste code, in accordance with Regulation №2 from 23.07.2014 for Waste Classification: 10 13 – Waste from the production of cement, lime, gypsum and items and products, made of these materials. 10 13 14 – Waste concrete and concrete sediment. 15 01 – Packages. 15 01 10 – Packages, containing residues of hazardous substances or contaminated with hazardous substances. Completely empty the packages and dispose them in accordance with the local regulations– at the indicated places for paper waste.
14. Transport Information
It is not a hazardous load, in accordance with RID, ADR, ADNR, IMDG, IATA-DGR. It should be transported under the respective rules for transportation, concerning the respective type of transport and ensuring the safety of the load.
15. Regulatory information
15.1 Classification and labeling of the product in accordance with Regulation (ЕО) 1272/2008 – CLP /full text of the codes/ GHS Pictograms:
GHS05
GHS07
Signal word: Danger! Recommendations for danger (N – codes): None. Hazard statements (H – codes): H315 – Causes skin irritation. H318 – Causes serious eye damage. H335 – May cause respiratory irritation. Precautionary statements (P – codes): P101 – If medical advice is needed, have product container or label at hand. P102 – Keep out of reach of children. P261 – Avoid breathing dust/fume/gas/mist/vapours/spray. P280 – Wear protective gloves/protective clothing/eye protection/face protection. P302 + P352 – IF ON SKIN: Wash with plenty of soap and water. P332 + P313 – If skin irritation occurs: Get medical advice/attention. P305 + P351 + P315 – IF IN EYES: Rinse cautiously with water for several minutes. Get immediate medical advice/attention. P402 – Store in a dry place.
15.2. LEGISLATION
National Legislation:
-
Law of Protection from the Harmful Impact of the Chemical Substances and Preparations
-
Environmental Protection Law
-
Health and Safety at Work Act
-
Ordinance №3 on the Minimum Requirements for Safety and Protection of Workers When Using Personal Protective Equipment at the Workplace
-
Waste Management Act
-
Ordinance №2 from 23.07.2014 for Waste Classification
-
Ordinance on the Order and Method of Classification, Labeling, and Packaging of Chemical Substances and Preparations
European Legislation:
-
Regulation (EC) 1272/2008 – CLP from 16th December 2008, concerning the classification, labelling, and packaging of substances and preparations
-
Regulation (EU) 830/2015 from 28th May 2015
16. Other Information
16.1. Indication of changes Format in accordance with Regulation (ЕО) 830/2015 from 28th May 2015 amending Regulation № 1907/2006 (REACH) of the European Parliament. 16.2. Training advice In addition to the training programs on environment and health and safety of the workers, the companies need to be sure that their workers read, understand and apply the requirements of the MSDS. 16.3. Additional information See the application(s) of exposure scenarios for the following substances: The basic information of the exposure scenarios of the substances in the mixture are included in points 1, 2, 3, 8, 11 and 12.
16.4. Disclaimer
This safety data sheet and the data inside of it are based on industrial and commercial experience of many years and are fully complied with the current active legislation of the Republic of Bulgaria and the European Union. This safety data sheet is not intended to guarantee any specific properties and qualities of the product. The information inside of it is reliable but, on the circumstance, that the product is used in accordance with the indicated conditions and the application, specified on the package and/or in the technical literature. Responsibility of any other use of the product, including when using it in combination with another product or process is completely under the responsibility of the user. It is understood that the user is responsible for defining the appropriate precautions and for applying the legislation, concerning his own activity.
Technical Data
Time for bucket stay | around 5 h. |
Open time for work | 30 min. (at 20°С) |
Ready for following operations | 7 days |
Thickness of applying of the plaster | minimum 4 mm |
Consumption | bonding 5-5.5 kg/m²; plastering: 3.5-4 kg/m² |
Package | 25 kg (gray) | 25 kg (white) |
Price | see price list | see price list |
Pieces | 48 pcs/pallet | 42 pcs/pallet |
Related Products
Products for therm-insulation systems
Facade finishing coats and paints
Facade finishing coats and paints
Facade finishing coats and paints
Facade finishing coats and paints
Facade finishing coats and paints
Facade finishing coats and paints
Primers and impregnators
Primers and impregnators
Additives for concrete